This abstract is published in the Journal of the American Society of Echocardiography (volume 33, number 6, year 2020), as part of the proceedings of the American Society Echocardiography Conference 2020.

Title: Fully Automated Quantification of Contrast and Non-Contrast Echocardiograms Eliminates Inter-Operator Variability

Authors: Beqiri, Arian and Parker, Andrew and Mumith, Angela and Hassanali, Neelam and Upton, Ross and Woodward, Gary and Dockerill, Cameron and Woodward, William and Alsharqi, Maryam and McCourt, Annabelle and others

BACKGROUND: Automated echocardiographic image analysis removes inter-operator variability which represents a major paradigm shift in current clinical practice and will facilitate the adoption of echocardiographic quantification and impact serial assessment of cardiac function by nonexperts in primary care and direct consumer settings. By using AI methods we built a fully automated and scalable analysis pipeline, robust enough for clinical application, to quantify echocardiographic measurements including global longitudinal strain (GLS) and ejection fraction (EF).

METHODS: Machine learning methods were developed using echocardiographic images to build a fully automated, AI platform for image processing that can segment the left ventricle (LV), select cycles and frames and quantify novel and standard metrics (i.e. GLS and EF) reproducibly. The automation framework was developed for 2 and 4 chamber views and short-axis (SAX) cardiac views using data obtained from a prospective multisite trial. The model to differentiate between contrast and non-contrast data was constructed using 86,941 images. The automated contouring model was developed on 5,692 and 2,182 frames for the contrast and non-contrast images, respectively. The training dataset for the SAX views consisted of 2,197 images. Cross-validation (CV) and hold out test data was used to evaluate the AI platforms. Segmentation reproducibility between 5 operators was assessed and compared to the variability observed using semi-automated routine applications.

RESULTS: A nominal AUROC of 0.998 was produced for the contrast/non-contrast detection model and the Dice Coefficient for auto-contouring accuracy was 0.932 and 0.924 for contrast and non-contrast images, respectively. In all cases of processing of the same images between operators, no variation was observed (0 RMSE, Bias and Limits of Agreement for EF, GLS and Volumes). Further, this inter-operator performance was far below that reported in the literature. A greater degree of inter-operator variation was observed for the semi-automated application under the same conditions (same images processed between operators).

CONCLUSION: Our pipeline demonstrates feasibility of a fully automated AI-based methodology to quantify echocardiography images in a robust platform that is scalable for analysis of echocardiograms within healthcare systems. The application is the first of its kind capable of processing contrast enhanced echocardiograms that completely eliminates inter-operator variability on image analysis.

Read on JASE: https://www.onlinejase.com/
volume 33, number 6, year 2020

Share on

Share on facebook
Share on twitter
Share on linkedin

Further reading

Ultromics and Mayo Clinic to Use AI to Improve Diagnosis of Heart Failure

●  Heart failure is the leading cause of hospitalization for people over the age of 65 – but diagnosis can be challenging and is often delayed through lack of …

AI Solution that Predicts Heart Disease To Be Implemented In NHS Hospitals

Ultromics’ EchoGo system selected among first winners of new £140m NHS AI in Health and Care Award  A pioneering AI platform that can predict heart disease will be implemented in NHS hospitals as …

What’s to Gain from Strain Imaging

Strain imaging techniques have shown great promise in echocardiography to support early signs of cardiac disease and is considered a more accurate and reproducible quantitative analysis of ventricular function and …