This abstract is published in the Journal of the American Society of Echocardiography (volume 33, number 6, year 2020), as part of the proceedings of the American Society Echocardiography Conference 2020.

Title: Fully Automated Strain Analysis at Rest and Peak Stress During Standard and Contrast Enhanced Stress Echocardiography

Authors: Hawkes, William and Beqiri, Arian and Mumith, Angela and Parker, Andrew and Upton, Ross and McCourt, Annabelle and Woodward, William and Dockerill, Cameron and Heitner, Stephen and Yadava, Mrinal and others

BACKGROUND: Strain imaging during stress echocardiography (SE) has proven to be a sensitive measure of left ventricular contractile function in suspected coronary artery disease (CAD). Using speckle tracking for strain imaging is limited at the higher heart rates and contrast enhanced imaging typically required for SE. Thus, we sought to train an Artificial Intelligence (AI) platform with fully automated contouring and strain analysis capabilities for use during SE.

METHODS: Bespoke machine learning methods were developed using SE images acquired at the different stages of a stress examination within a prospective multisite study. A fully automated AI platform for left ventricle (LV) segmentation, and cycle and frame selection was developed to allow quantification of standard metrics (i.e. GLS and ejection fraction). The automation framework was developed for two and four chamber cardiac views, both with and without contrast enhancement. The automated contouring model was developed on 5,692 and 2,182 frames for the contrast and non-contrast images, respectively. The ability of the auto-strain model to evaluate GLS during SE was then studied by comparison of mean GLS in patients with and without CAD, based on clinical and angiographic outcome.

RESULTS: Calculation of GLS in dataset 1 (578 patients, 85 with clinically proven CAD) demonstrated significantly reduced (p<0.01) GLS at peak stress (-14.7±5.4 vs -19.7±5.4) and smaller increases in GLS from rest to peak stress (ΔGLS = GLSpeak – GLSrest, -0.9±5.5 vs -2.8±5.8) in CAD positive patients. In dataset 2 (154 patients, 45 with CAD positive outcomes), containing only contrast enhanced images, CAD patients also exhibited significantly reduced peak GLS (-12.1±3.3 vs -17.8±4.11) and ΔGLS (2.0±5.0 vs -1.7±5.0). ROC curve evaluation for diagnostic performance demonstrated AUROC values of 0.76 (sensitivity=0.78, specificity=0.62) and 0.85 (sensitivity=1.0, specificity=0.49) for peakGLS using -18.3 as the cut-off.

CONCLUSIONS: We have demonstrated that AI processing of images acquired during routine SE is possible and allows automatic contouring and quantification of GLS. This ability to conduct a fully automated SE strain analysis presents an exciting opportunity for the reduction variability in clinical interpretation and decision making, in cases suspected CAD.

Share on

Share on facebook
Share on twitter
Share on linkedin

Further reading

$10m funding accelerates innovation and growth for EchoGo

Artificial intelligence (AI) health-tech company Ultromics announced today it has  closed a $10 million financing round to accelerate its next stage of business growth. The capital has been raised …

Off-cart analysis and diagnosis can enhance workflow efficiencies and reduce exposure to COVID

Healthcare systems are accustomed to adapting to change, but the current COVID-19 crisis is unique. Whilst many past changes to healthcare delivery have allowed for technology adoption over time …

Ultromics collaborates with Mayo Clinic to optimize the impact of AI tools on care pathways

Ultromics, a health-tech company which applies AI to echocardiography, to earlier detect and better diagnose heart disease, has entered a know-how and clinical research agreement with Mayo Clinic. Underpinned …